Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the quiri-hydromecanique-i18n domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/lafabrikk.dev/qri.lafabrikk.dev/wp-includes/functions.php on line 6114
Steam condenser : Shell and tube heat exchangers - Quiri close pdf print video more home burger search arrow

Hydraulic cylinders and components, hydraulic systems, gas springs & shell and tube heat exchangers : Quiri

Steam condenser

Industries concerned : 
Product concerned : Shell and tube heat exchangers
Steam condenser : Shell and tube heat exchangers - Quiri
At a time when all thermal systems ensure maximum efficiency, condensate heaters allow maximum energy recovery and thus contribute to climatic issues.

Thermal Specificities:

 

Quiri, as a specialist of heat exchangers, can provide you a condensate reheater / vapour condenser

 

Equipment delivered in England in 2018, as part of the manufacturing of a waste facility combined with a power plant.

The project will be able to generate up to 43MW per year of electricity from the incineration of household waste for the region and provide steam for a paper mill.

The condensate reheater supplied by Quiri is part of a set of 4 heat exchangers: two condensate reheaters, one feedwater heater and one dearator vapour condenser.

The function of these shell & Tubes exchangers is to reheat condensates from the steam coming from the upstream turbine.

The heat exchanger, of Quiri thermal design, condenses the steam with an integrated sub-cooling system of the condensed steam.

 

 

Some Technical Data :

Shell Side Tube Side
Nature of the fluids Steam / Gas 2 Water / Liquid 2
Number of passes 1 4
Service Temperature (inlet / outlet) °C 81.56

(Saturation)

48 43.4 75.6
Service Pressure Bar (a) 0.5 20.5
Main Dimensions
Power MW 10.5
Exchanged Area Installed 392
Bundle tubes Type Bended U-tubes
Shell Diameter mm 1000

 

 

Geometric Specificities :

 

Horizontal tubular heat exchanger, overall length 8500 mm, empty weight 10 Tons.

Shell & Tube Exchanger , type BXU – with removable head and bundle

 

 

Construction Specificities:

 

Code : EN 13445

Regulation: DESP 2014/68/UE

Calculation temperature:  -10°C /150°C tube side and shell side

Design pressures: -1/ +.30 bar (g) tube side and shell side

Test pressures: 44 bar (g) tube side and shell side

Risk category IV, reception modula G

Welding coefficient 0.85

 

Metallurgy :

  Material Norm
Shell P265 GH EN 10028-2
Tubesheets P355 QH EN 10222-2
Flanges P355 QH EN 10222-2
Head P265 GH EN 10028-2
Bundle tubes 1.4404 EN 10216-5
Tubes Gr6 ASTM A333
Baffles S235JRG2 EN 10025

 

Tubes / Tubesheet connection: welding and expansion

Welding procedures: EN ISO 15614-1 or EN 288.3

Welders certifications: According to EN 287.1 or EN 1418

Semi-automatic MIG/MAG processes

 

 

Quality Specificities:

 

Quality Plan according to client specifications, to the requirements of European and local regulations.

Data log book in English.

Equipment installed in England; the CDM (Construction Design and Maintenance) Regulations 2015 were applicable to the project.

Employees trained and approved for CDM 2015