Extensions are fixed on standard snubbers (DAST) and low temperature snubbers (DALT), fabrication on demand.
Hereofter some dimensions, (other extensions size on demand). Adjustment of the rear eyes: +/- 35mm
For DAST and DALT |
Nominal Load Level B |
Faulted Load Level D |
A maxi half stroke |
Ø G | L mini |
L maxi |
C | Ø D | E | F1 | F2 | R1 | R2 | Weight | 3D Model |
|
L mini |
+ per 50mm |
|||||||||||||||
(kN) | (kN) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (kg) | (kg) | ||
DA1-100 | 14 | 24 | 1000 | 40 | 190 | 540 | 50 | 17 | 20 | 19 | 13 | 28 | 26.5 | 14 | 0.22 | 3D |
DA1-200 | 14 | 24 | 1000 | 40 | 190 | 340 | 50 | 17 | 20 | 19 | 13 | 28 | 26.5 | 19 | 0.22 | 3D |
DA2-150 | 30 | 19 | 1400 | 60 | 200 | 800 | 50 | 20 | 25 | 23 | 17 | 28 | 32 | 25.5 | 0.34 | 3D |
DA2-300 | 30 | 19 | 1400 | 60 | 200 | 450 | 50 | 20 | 25 | 23 | 17 | 28 | 32 | 33.5 | 0.34 | 3D |
DA3-150 | 47 | 77 | 1700 | 80 | 220 | 1120 | 60 | 25 | 28 | 28 | 19 | 32 | 36.5 | 39 | 0.46 | 3D |
DA3-300 | 47 | 77 | 1700 | 80 | 220 | 820 | 60 | 25 | 28 | 28 | 19 | 32 | 36.5 | 53 | 0.46 | 3D |
DA4-150 | 100 | 140 | 2100 | 100 | 250 | 1500 | 70 | 30 | 32 | 30 | 21 | 39 | 41 | 72 | 1.1 | 3D |
DA4-300 | 100 | 140 | 2100 | 100 | 250 | 1150 | 70 | 30 | 32 | 30 | 21 | 39 | 41 | 76 | 1.1 | 3D |
DA5-150 | 200 | 280 | 2100 | 120 | 260 | 1410 | 105 | 45 | 43 | 40 | 30 | 58 | 56 | 100 | 1.4 | 3D |
DA5-300 | 200 | 280 | 2100 | 120 | 260 | 1060 | 105 | 45 | 43 | 40 | 30 | 58 | 56 | 121 | 1.4 | 3D |
Adjustment ± 35mm.