Supplied through counter-bores under the head or taps
quiri-hydromecanique-i18n
domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init
action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/lafabrikk.dev/qri.lafabrikk.dev/wp-includes/functions.php on line 6114Double-acting - with rotation travel
Max force at 250 bar: 1.9 kN
Supplied through counter-bores under the head or taps
• total travel 17 mm
• clamping travel 6 mm
• right or left helical rotation, 90°±2°
• clamping arm: see accessories
• 60°, 45° or 0° angle of rotation on request
• special models on request
• nozzle for supply through counter-bores
The clamps are supplied with seals, ring, and O-rings, 5.25 x 1.78 – 90 Shore.
(Dimensions and tightening torque : see Clamping arm for swing clamp).
F max
at 250 bar |
Flow rate
max A
|
Flow rate
max B
|
Swept
volume A B |
Section
A B |
Direction of rotation
|
Type | Reference | |
|
||||||||
kN | l/min | l/min | cm3 | cm2 | ||||
1.9 | 0.2 | 0.36 | 1.67 | 0.98 | right | HL 5 D | 191 169/050 | |
3 | 1.77 | left | HL 5 G | 191 169/150 |