The function of the pressure reducer is to maintain constant receiver side pressure (secondary circuit) in spite of a higher variable input pressure (primary circuit). This model is made up of a valve that is leak-free when it is closed (no need for draining oil port). When the primary pressure level at P is less than the secondary pressure at A, reversed flow from A to P for the valve (which is then open) is possible.
Type | Reference | ||||
Pressure
range |
Max flow
rate |
||||
bar | l/min | ||||
RDP 3 | 1 | T | A 66 277 | 15 to 130 | 12 |
2 | A 66 325 | 20 to 200 | |||
3 | A 66 324 | 30 to 300 | |||
RDP 3 | 1 | P | A 66 323 | 15 to 130 | 12 |
2 | A 66 288 | 20 to 200 | |||
3 | A 66 322 | 30 to 300 | |||
RDP 3 | 1 | C | A 66 321 | 15 to 130 | 12 |
2 | A 66 320 | 20 to 200 | |||
3 | A 66 319 | 30 to 300 | |||
RDP 3 | 1 | R | 354 008/400 | 15 to 130 | 12 |