action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/lafabrikk.dev/qri.lafabrikk.dev/wp-includes/functions.php on line 6114Test pressure: 500 bars
Max working pressure: 350 bars
HELD IN STOCK
TYPE | Units | S48 40 | S48 50 | S48 63 |
Piston | (mm) | 40 | 50 | 63 |
Rod | (mm) | 22 | 28 | 36 |
Pushing force at 100 bars | (kN) | 12.5 | 19.6 | 31.1 |
Pulling force at 100 bars | (kN) | 8.7 | 13.4 | 21 |
L (strokes from 5 to 80 mm) | (mm) | 165 | 175 | 188 |
L (strokes from 85 to 120 mm) | (mm) | 205 | 215 | 228 |
L (strokes from 125 to 160 mm) | (mm) | 245 | 255 | 268 |
L (strokes from 165 to 200 mm) | (mm) | 285 | 295 | 308 |
a | (mm) | 90 | 100 | 120 |
b | (mm) | 76 | 86 | 106 |
c | (mm) | 10 | 10 | 12 |
e | (mm) | 34 | 35 | 42 |
f | (mm) | 72 | 82 | 98 |
g | (mm) | 11 | 11 | 13 |
g1 x depth | (mm) | ø17 x 11 | ø17 x 11 | ø19 x 13 |
h | (mm) | 60 | 60 | 72 |
j H8 | (mm) | 8 | 10 | 12 |
k | (mm) | 45 | 50 | 60 |
v | (mm) | 9 | 9 | 10 |
w x depth | (mm) | ø20.5 x 2 | ø20.5 x 2 | ø22.3 x 2 |
z | (mm) | 5 | 5 | 5 |
z’ (+0.1 0) | (mm) | 5 | 5 | 5 |