Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the quiri-hydromecanique-i18n domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/lafabrikk.dev/qri.lafabrikk.dev/wp-includes/functions.php on line 6114
INFLATING & PRESSURISING GAS SPRINGS - Quiri Group close pdf print video more home burger search arrow

Hydraulic cylinders and components, hydraulic systems, gas springs & shell and tube heat exchangers : Quiri

Home » Quiri Hydromécanique » Gas Springs » Inflation units » INFLATING & PRESSURISING GAS SPRINGS

INFLATING & PRESSURISING GAS SPRINGS

Print this guide

Inflating process of gas springs connected for equal pressure

• Confirm that the pressure reducer has been connected to the nitrogen bottle and adjust the output pressure to 150 to 155 bar (15 to 1.5 MPa).
• Connect the adapters to the inflating unit.
• Connect the inflating unit to the control panel.
• Close the pressure reducer.
• Open the nitrogen bottle.
• When the inflating gauge indicates the pressure that you need, please wait for a while (about 10 seconds), the piping system pressure will stabilize.
• Close the nitrogen bottle.
• Open discharging valve to release the pressure.
• Remove the inflating unit from the control panel.

INFLATING & PRESSURISING GAS SPRINGS : Inflation units - Quiri

Control block with G1/8″ adapter

To inflate the piping system with standard G1/8″ adapter, you can use standard inflating units and G1/8″ adapter.

INFLATING & PRESSURISING GAS SPRINGS : Inflation units - Quiri - 2

Control block with CEJN adapter

You can use self-lock fast coupling adapter to connect it.
Notice : The fast coupling should be ordered with inflating units separately. The pressure reducer should be ordered separately.

INFLATING & PRESSURISING GAS SPRINGS : Inflation units - Quiri - 3

Ajust the pressure of gas springs

The inflating device is designed to pressurize and depressurize gas springs
Use of the device as a pressure tester is not recommended, as each test result leads to a loss of pressure of approximately 10 %.
The pin ø4 mm is designed to depressurize a gas spring, but is not required for pressurizing.

Each pressurising kit (Code 841046/000) includes :
• 1 pressurizing assembly (Code : A63295) with gauge 0-250 bar + flexible hose (2m) + valve spanner.
• 1 adapter MM M33x1,5 – G1/8’’ + 1 pin ø4 to direct inflating in G1/8’’ threads (Code : 831050/000)
• 1 adapter MF 1/16NPS – G1/8’’  (Code : 831052/000)
• 1 adapter MF M6 – G1/8’’  type A (Code : 831101/000)
• 1 adapter MF M6 – G1/8’’  type B (Code : 831113/000)

MOUNTING A – Inflating directly with the adapter

INFLATING & PRESSURISING GAS SPRINGS : Inflation units - Quiri - 4

MOUNTING B – Inflating with adapter and tip

INFLATING & PRESSURISING GAS SPRINGS : Inflation units - Quiri - 5
Type of Gas spring Mounting Tip to use
RG 19 B 831113/000
MRG B 831113/000
RMG/T/E B 831052/000
RG 32 B 831113/000
RG 300 F B 831052/000
RGP 170 à RGP 2400 B 831113/000
RGP 4200 à RGP 9500 A Direct sur adaptateur
RGT 1000 à RGT 9500 A Direct sur adaptateur
RGC 420 et RGC 750 B 831113/000
RGC 1000 à RGC 3000 B 831101/000
RGC 4700 à RGC 18300 A Direct sur adaptateur
RGH B 831113/000
RG 250 A Direct sur adaptateur
RG 500 C10 à C100 A Direct sur adaptateur
RG 500 C125 à C160 B 831101/000
RG 750 C13 à C160 A Direct sur adaptateur
RG 750 C200 à C300 B 831101/000
RG 1500 à RG 10000 A Direct sur adaptateur

Procedure

To reduce the pressure (P<150 bar) of a gas spring, please proced as followed :
• Unscrew the plug of the filling valve
• Depressurize the gas spring completely by depressing the valve with the special QUIRI tool, whilst keeping the piston rod of the gas spring fully extended.
• Refill the gas spring to the required pressure level (eg. 100 bar).
• Check the valve tightness with a drop of oil inside the pressuring orifice.
• If the valve is not tight, replace it with new one.
Do not forget to indicate the new inflating pressure on the gas spring body and identify if with a blue adhesive strip if the new pressure is lower than 150 bar.

INFLATING GAS SPRINGS WITH 2 NITROGEN BOTTLES

THE ADVANTAGE OF THAT EQUIPMENT IS THE OPTIMAL USE OF NITROGEN BOTTLE CONTENTS
• At first, use bottle A only
• After several usages, the pressure in bottle A will be lower than initial pressure (15MPa). Then you can use bottle B to add the missing pressure.
Example : bottle A contains 13.5 MPa, use bottle B to add 1.5 MPa. You can use bottle A until bottle B is lower than 15Mpa.
• Then you should replace bottle A by a new one, and bottle B becomes bottle A

Inflating advice :

• Open valve A and close valve B, then fill the gas spring with maximum pressure from the bottle A.
• Close valve A and open valve B, then fill the gas spring with about 155 bar.
INFLATING & PRESSURISING GAS SPRINGS : Inflation units - Quiri - 6

INFLATION OF CONTROL PANEL EQUIPED WITH STAUBLI CONNECTOR WITH 2 NITROGEN BOTTLES

THE ADVANTAGE OF THAT EQUIPMENT IS THE OPTIMAL USE OF NITROGEN BOTTLE CONTENTS

Inflating advice :

• First of all, setup the inflating pressure on the pressure reducer.
• Connect the STAUBLI connector to the control panel.
• Open valve A and close valve B, then fill the gas spring with maximum pressure from the first bottle.
• Close valve A and open valve B, then fill the gas spring with about 155 bar.
• Close valve B and the valves on the nitrogen bottle.
• Open discharging valve on the collector to remove pressure.
• Disconnect the STAUBLI connector by pushing the knob.
WARNING! : NEVER REMOVE THE CONNECTOR WHILE UNDER PRESSURE.

INFLATING & PRESSURISING GAS SPRINGS : Inflation units - Quiri - 7